Water can travel along a cable after entering an exposed end or another opening, even when a connector seals correctly around the outer jacket. Whether it does so depends on the cable's construction, the available paths and the exposure. A connector's ingress claim does not by itself establish longitudinal water blocking inside that cable. For waterproof cable connectors, specify where water could enter, where it must be stopped, and what evidence demonstrates that boundary in the finished assembly.
Draw two different water paths
Imagine a cable entering an otherwise dry control enclosure. A gland can seal around its outer jacket while the far end is damaged or open in a wet location. The first boundary concerns water crossing the outside of the cable at the entry. The second concerns water travelling inside the cable towards the enclosure. Improving the outside seal does not automatically close that internal route.
LAPP distinguishes transverse protection, which resists penetration through the cable's outer materials, from longitudinal protection, which limits spread along the cores after water reaches an end. Its explanation gives a filling compound as one possible blocking feature. This describes a cable construction principle; it does not establish that a particular KMYD cable contains such a feature.
For an investigation, mark the cable jacket, individual insulated cores, termination regions, joints and open ends on one sketch. Ask the cable manufacturer which spaces could provide a continuous route. The term “wicking” is useful shorthand, but it should not replace identifying whether the suspected path involves conductor strands, spaces between components or a damaged interface.

Follow the route past the connector
The water boundary may be at the connector, inside a cable section, at a splice or at the enclosure end. An assembly drawing should make that location explicit. A requirement to “keep the controller dry” is incomplete unless the supplier knows which portions of the wiring can be wet and which openings or faults the design is intended to address.
Consider these questions in order:
- Where can water gain access? Distinguish normal exposure of an intact assembly from an exposed free end, a service joint or a damaged jacket. They need not be covered by the same qualification.
- Which length is vulnerable? Identify the section between the possible entry and the protected equipment, including every intermediate termination.
- What is the claimed stopping feature? Request the applicable drawing or construction specification. An external molded shape is not evidence that every internal path is blocked.
- How is the claim verified? Define a representative finished specimen and an observation method that can distinguish movement inside the cable from leakage around its exterior.
Do not assume that all cables with the same diameter behave alike. A substitute may fit the connector's cable entry while changing the internal water paths. The manufacturer therefore needs the specific cable identity and construction revision when assessing a longitudinal requirement.
Ask the test to answer the internal-path question
A suitable evidence plan identifies the wetted end or region, water conditions, pressure difference where relevant, temperature, duration, cable length and orientation. These are specification fields, not universal test values. The responsible engineer or laboratory must choose them from the application and the applicable product documentation.
The observation point matters as much as the exposure. Water seen at the dry end needs to be distinguished from water carried there on the outside during handling. Define how the specimen will be supported, how external carryover will be controlled, and what counts as migration or an unacceptable result before the assessment begins. A negative finding means only that no migration was detected under those stated conditions and measurement limits.
An ingress test on a fully closed connector pair may be useful for another boundary. It does not necessarily challenge an open cable end, and it should not be presented as proof that such an end cannot transport water. Keep the two claims separate in the purchase specification.

Put the stopping boundary on the cable drawing
The SP series cable assembly listing provides a starting product reference. If the project needs a defined longitudinal water boundary, use the custom SP cable assembly route to submit the boundary sketch and cable exposure conditions for assessment. That request does not presume a water-blocking option is available.
Make the response identify the proposed construction, any excluded damage or open-end conditions, and the evidence still needed. Then bind the accepted cable and termination revisions to the drawing. This gives purchasing a specific requirement to preserve when a cable or connector component is later substituted.
Technical reference: LAPP explanation of transverse and longitudinal cable watertightness.